NW40 | ISO63 | CF63 | ISO100 | |||||
Inlet Pumping Speed ls-1 | N2 | 48 | 84 | 85 | ||||
Ar | 44 | 80 | 80 | |||||
He | 61 | 79 | 77 | |||||
H2 | 50 | 61 | 54 | |||||
Compression Ratio | N2 | >1 x 1011 | ||||||
Ar | 1 x 109 | |||||||
He | 8.5 x 106 | |||||||
H2 | 2.1 x 105 | |||||||
Interstage Pumping Speed (70 sccm gas load) ls-1 | N2 | 6 | ||||||
Ar | 6 | |||||||
He | 9 | |||||||
H2 | 10 | |||||||
Backing/Interstage Port Size | NW16 | |||||||
Vent/Purge Port | NW16 | |||||||
Maximum Continuous Inlet flow N2 | ||||||||
Forced Air Cooled (35 oC ambient) | sccm | 30 | ||||||
Forced Air Cooled (23 oC ambient) | sccm | 60 | ||||||
Water Cooled (35 oC ambient) | sccm | 50 | ||||||
Water Cooled (23 oC ambient) | sccm | 60 | ||||||
Natural Convection (30 oC ambient) | sccm | 10 | ||||||
Natural Convection (23 oC ambient) | sccm | 25 | ||||||
Maximum Continuous Backing Pressure N2 | ||||||||
Forced Air Cooled (35 oC ambient) | mbar | 10 | ||||||
Forced Air Cooled (23 oC ambient) | mbar | 16 | ||||||
Water Cooled (35 oC ambient) | mbar | 10 | ||||||
Water Cooled (23 oC ambient) | mbar | 16 | ||||||
Natural Convection (30 oC ambient) | mbar | 1 | ||||||
Natural Convection (23 oC ambient) | mbar | 2 | ||||||
Start Time to 90% Speed (80 W) | sec | 115 | ||||||
Nominal Rotational Speed | rpm |
90,000 |
||||||
Mass | kg |
3.0 |