Previous | 3 / 4 | Next |
Inlet flange | VG200/ ISO200F/ ICF253 | VG250/ISO250F/ ICF305 |
Backing port size | KF40 | KF40 |
Pumping Speed | ||
N2 | 1850 ls-1 | 2200 ls-1 |
H2 | 1250 ls-1 | 1350 ls-1 |
Ar | 1650 ls-1 | 2000 ls-1 |
Compression ratio | ||
N2 | >108 | >108 |
H2 | 1 x 103 | 1 x 103 |
Ultimate pressure | 10-7 Pa (10-9 Torr) | 10-7 Pa (10-9 Torr) |
Max working pressure | ||
Allowable backing pressure | 266 Pa (2 Torr) | |
Rated speed | 36,500 rpm | |
Run-up time to 90% rated speed | ||
Starting time | ¨Q10 min | |
Mounting position | Any orientation | |
Cooling method | Water cooling | |
Lubricating oil | Not necessary | |
Backing pump | - | |
Leakage Magnetic Flux | ||
Axial direction | - | |
Radial direction | - | |
Ambient temperature range | 0 to 40 °C | |
Storage temperature range | -5 to 55 °C | |
Input voltage | 200 to 240 V a.c. | |
Maximum input power | 750 VA | |
Weight | 48 kg |